document_0900452a81b1b9de.book Seite 261 Donnerstag, 26. Juli 2007 9:16 09
Checking and topping up fluids 261
• The coolant additive G12++ can be mixed only with additives If there are no leaks in the system, a loss of coolant can only occur
G12+ and G12. if the coolant boils and is forced out of the system as a result of
overheating.
Checking coolant level
The coolant level can be checked at a glance. Caution
Radiator sealants must not be added to the coolant. Such additives
could seriously impair the function of the cooling system.
Topping up the coolant
Be careful when topping up coolant.
– Switch off the engine.
Fig. 257 Engine
compartment: Mark- – Wait for the engine to cool down.
ings on radiator expan-
sion tank – Cover the cap on the expansion tank ⇒ fig. 257 with a
cloth, and carefully unscrew the cap anti-clockwise
– Switch off the ignition. ⇒ .
– Read off coolant level on radiator expansion tank – Add coolant.
⇒fig.257. When the engine is cold it should be between – Screw the cap on again tightly.
the “MIN” and “MAX” marks. When the engine is hot it
may be slightly above the “MAX” mark. Make sure that the coolant meets the required specifications
The coolant level should be checked with the engine switched off.⇒page260, “Coolant”. Do not use a different type of additive if anti-
freeze additive G12++, G12+ or G12 is not available. In this case use
The coolant level is monitored by a warning lamp in the instrument only water and bring the coolant concentration back up to the
cluster ⇒ page 33. However, we recommend that it should be correct level as soon as possible by putting in the specified additive.
checked occasionally. Always top up with fresh, unused coolant.
Coolant losses Do not fill above the “MAX” mark. Excess coolant is forced out of the
Any loss of coolant normally indicates a leak in the cooling system. system through the valve in the filler cap when the engine gets hot.
In this case the cooling system should be inspected by a qualified If a lot of coolant has been lost, wait for the engine to cool down
workshop without delay. It is not sufficient merely to top up the before putting in cold coolant. Failure to do so could result in
coolant. serious engine damage.
Controls Safety Driving tips General maintenance Self-help Technical data
Download PDF
Click here to download a pdf file with an instruction manual for Audi A4
year of production from: 2008
Do you prefer pdf format?
Find out how to download
Enter the code to download PDF file:
All pages in one PDF file!
How to get the code?
It's very simple! Just pay through a secure PayPal payment.
It will take no longer than a few minutes.
You will receive the code immediately after payment.
The code will be displayed on the screen and will be sent to you by e-mail address.
:
Audi A4 B8 owners manual
pages 260 - 266
Audi A4 B8 owners manual
page 263 / 342
this site is maintained by advertising - for view instructions, turn off ad blocking in your browser
Download PDF